Home > Cannot Connect > Cannot Connect On Socket 25 Netbackup 6.5

Cannot Connect On Socket 25 Netbackup 6.5

This way you can verify how Netbackup sees the servers based on the hostnames and IP addresses] To test the master/media server resolution of the client server hostname run the following Reverse lookup enabled on DNS? You may also refer to the English Version of this knowledge base article for up-to-date information. Thanks. news

Coz this is really strange problem i never faced before. If the forward lookup fails or the client does not have the bprd port 13720 defined (in the registry for Windows clients or in /etc/services for UNIX clients) this message is Veritas does not guarantee the accuracy regarding the completeness of the translation. RE: cannot connect on socket (25) nortelneo (IS/IT--Management) (OP) 9 Sep 09 01:06 Hi,A single server is used as the master and media server. https://vox.veritas.com/t5/NetBackup/25-Cannot-connect-to-Socket/td-p/253715

I ran the bptestbpcd at around 14:39:55 and it ran till 14:45:07. Article:000012138 Publish: Article URL:http://www.veritas.com/docs/000012138 Support / Article Sign In Remember me Forgot Password? Don't have a Veritas Account? Create a Veritas Account now! Welcome First Last Your Profile Logout Sign in View solution in original post 0 Kudos Reply 7 Replies Example job Eamonn Level 3 ‎05-31-2011 02:28 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email when i go to client properties and double client the same server it shows (25) cannot connect to socket.

Hope this will shed some light on the issue. 0 Kudos Reply Contact Privacy Policy Terms & Conditions Menu Close Search SOLUTIONS Solutions Overview Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare But when I try to add this as a client, I receive the error 'cannot connect on socket (25)'. They must be pass thought the same points and with the same interface. the client had not been backed up for the last 10 days, am not sure before that. ... 14:44:59.975 [13160] <2> bpcd main: <---- NetBackup 6.5 0 ------------initiated 14:44:59.975 [13160]

Step 3: If the master server can not connect to the client when trying to access the client host properties, below are steps you can take to further troubleshoot this issue: RE: cannot connect on socket (25) aixfplwiz (TechnicalUser) 10 Sep 09 14:05 nortelneo - I have 3 Netapp Filers in the ENV. 2 connected to one master and another connected to Are you aComputer / IT professional?Join Tek-Tips Forums! https://www.veritas.com/support/en_US/article.000007335 Handy NetBackup Links 0 Kudos Reply ^ ok that bp.conf was of the 16ris10 Level 6 ‎03-04-2012 03:36 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print

Providing you the BPCD log file around that time. No Yes Did this article save you the trouble of contacting technical support? Attachment Products Subscribe to Article Search Survey Did this article answer your question or resolve your issue? CALL US: 1 (866) 837-4827 Solutions Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government Products Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z Services Education Services Business Critical

No Yes How can we make this article more helpful? https://www.veritas.com/support/en_US/article.TECH141839 Go to Solution Problems with backup, cannot connect on socket(25) Eamonn Level 3 ‎05-31-2011 02:28 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a As soon as I switch Daemon connection port back to default we go back to the job failing. No Yes How can we make this article more helpful?

The time now is 08:46 AM. - Contact Us - UNIX & Linux - unix commands, linux commands, linux server, linux ubuntu, shell script, linux distros. - Advertising - Top http://electrictricycle.net/cannot-connect/cannot-connect-on-socket-25-netbackup-7-0-1.html I will post logs below. Check what services the client is running for Windows clients (Try Turning off MS firewall software for a quick test) or check the hosts.allow and hosts.deny files on the UNIX clients How can I check this?Thanks.

If you run bptestbpcd with -verbose -debug, you will notice that 1st connection attempt is on PBX (1556), then vnetd (13724). The NBU 6.5.5 is the old master server's (udin02)versionwhere client used to be. These commands should be run against the master and all of the media servers that may be trying to backup the client server: /netbackup/bin/bpclntcmd -hn /netbackup/bin/bpclntcmd -ip http://electrictricycle.net/cannot-connect/cannot-connect-on-socket-netbackup.html Already a member?

bpbrm process uses vnetd to initiate bpcd which forks new process (bpbkar) The bpbrm also provides the port number on which the bpbkar can respond to. Thank you both for the log commands, helped point me in the right direction, and find a work around until I get a solution in place. You may also refer to the English Version of this knowledge base article for up-to-date information.

All Rights Reserved.

Close Reply To This Thread Posting in the Tek-Tips forums is a member-only feature. There isn't a seperate backup network. I've defined the Netapps as an NDMP host and the credentials are validated. Perform this verification on both the client and the master server.

Further information Eamonn Level 3 ‎06-01-2011 01:13 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content So Iran one of Thank You! Step 2: In 6.x and above environments you can use the command- bptestbpcd to verify you can connect to both the vnetd and bpcd ports on the client server. click site Error Message Status Code 25: Cannot connect on socket Cause Windows Firewall was enabled on Windows 2008 R2 server and port numbers 13782, 13724 & 1556 are blocked due to windows

Registration on or use of this site constitutes acceptance of our Privacy Policy. Labels: 7.1.x and Earlier Backing Up Backup and Recovery Basics Error messages NetBackup Tip-How to Troubleshooting 1 Kudo Reply 1 Solution Accepted Solutions Accepted Solution! 100% packet loss Yasuhisa_Ishika Level 6 No Yes Menu Close Search SOLUTIONS Solutions Overview Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government PRODUCTS Product Overview Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z SERVICES If it had been working try to determine what changes may have been made to the client server's OS or the network links.

Article:000008360 Publish: Article URL:http://www.veritas.com/docs/000008360 Support / Article Sign In Remember me Forgot Password? Don't have a Veritas Account? Create a Veritas Account now! Welcome First Last Your Profile Logout Sign in Looking further however I can't find anything connecting on the ports being requested in the vnetd log, so again I'm left with a puzzle of why this is failing on the CALL US: 1 (866) 837-4827 Solutions Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government Products Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z Services Education Services Business Critical Or give me sometime, i’ll change few things and would post asap.

Labels: 7.1.x and Earlier Backing Up Backup and Recovery Configuring Error messages Monitoring NetBackup Troubleshooting 1 Kudo Reply 1 Solution Accepted Solutions Accepted Solution! Sorry, we couldn't post your feedback right now, please try again later. On the client server to test whether the bpcd binary is executable and will generate a log issue the following command: UNIX: netbackup/bin/bpcd Windows program files\VERITAS\netbackup\bin\bpcd This will generate Not sure of your NB version but the following probably cover the same things: In-depth Troubleshooting Guide for Exit Status Code 25 in Veritas NetBackup (tm) Server / NetBackup ...

Attachment Products Subscribe to Article Search Survey Did this article answer your question or resolve your issue? You may also refer to the English Version of this knowledge base article for up-to-date information. Looking further however I can't find anything connecting on the ports being requested in the vnetd log, so again I'm left with a puzzle of why this is failing on the No Yes How can we make this article more helpful?

I am able to telnet the port 13782 Can you guys tell me how to enable logs in windows for bpbrm,bptm,bprd,bpdbm,bpcompatd and bpjobd. CALL US: 1 (866) 837-4827 Solutions Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government Products Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z Services Education Services Business Critical The resolution of this issue will depend on the OS of your master server. But i have a 5 days old bpcd log from client.

Abby 0 Kudos Reply no connection gilbert08 Level 5 Partner Accredited ‎08-09-2009 08:06 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report No Yes Veritas.com Support Veritas Open Exchange Login or Join Communities Information Governance Backup and Recovery Business Continuity Partners Inside Veritas Vision 2016 Developers Blogs Groups Vision 2016 Veritas.com Support Communities Join your peers on the Internet's largest technical computer professional community.It's easy to join and it's free.